Anderson plug cable size calculator
Enter the current your Anderson circuit carries and the one way cable length from battery to plug. The calculator shows how many volts you lose in the cable and the smallest common Australian cable size that keeps the loss under your limit.
| Cable | Copper | Drop | Arrives |
|---|
Formula: drop = 2 × length × amps × 0.0172 ÷ copper area in mm² (copper at 20 °C; expect a little more when the cable is hot). Copper areas are typical figures for Australian cable and vary slightly by maker.
Length means one way
Measure the cable run from the battery to the Anderson plug. The calculator doubles it for you because current flows out on the positive and back on the negative.
6 mm auto cable is not 6 square millimetres
Australian auto cable is named by its outside diameter including insulation. 6 mm auto cable has roughly 4.59 mm² of copper. B&S sizes are much heavier: 8 B&S is about 7.7 mm² and 6 B&S about 13.5 mm². That gap is why a circuit wired in 6 mm auto often underperforms.
What fits a 50 A Anderson plug
Standard SB50 contacts are made for 6 B&S cable. Contacts for 8 B&S and smaller cable are sold separately, so buy the contact that matches your cable instead of packing out a loose crimp.
Voltage drop is not the only limit
The cable also has to carry the current without overheating, and the circuit needs a fuse or breaker close to the battery sized to protect the cable. Check the current rating on the cable you buy.
Made for this plug
Once the cable is right, look after the plug on the end of it.
Anderson Plug Holder / Parking BracketParks the loose Anderson lead on the drawbar or A-frame so the contacts are not dragging in the dirt.$19.95 · free postage Australia wideBuy on Etsy
Anderson Plug 50A Dust CapKeeps dust and water out of a loose 50 A Anderson plug. Snap on fit, lanyard tab, UV stable ASA.$12.95 · free postage Australia wideBuy on Etsy